The WITT Automatic Flashback Arrestors RF 53 N, 85-10 and 85-30 incorporate:
WITT Automatic Flashback Arrestors RF 53 N, 85-10 and 85-30 conform to EN 730-1, ISO 5175 and other national standards.
Tests: Every WITT Arrestor is tested individually for body leaks, non-return valve funktion and is subjected to flashback testing at the maximum rated operating pressure in accordance with ISO standards or those of the country of sale.
Maintenance: No maintenance is required. Nevertheless it is recommended that at annual intervals the units are tested with clean dry air or nitrogen for body leakage and against reverse flow.
Test specifications and test equipment available on request.
Installation: The WITT Automatic Flashback Arrestor may be installed at regulator or pipeline outlets. For pipeline use a shut-off valve should be fitted immediately upstream of the arrestor. If there is a danger from water vapour being carried with the gas, then a seperator should be installed upstream. Not more than one process unit may be connected to one flashback arrestor. It may be mounted horizontally, vertically or any other position. The maximum working temperature is 70° C.
Repairs: Detective units as well as units with temperature activated cut-off valve closed should only be serviced by the manufacture or his authorised local representative as it requires full testing including flashback testing after reassembly. The change of the dirt filter is not part of this requirement and can easily be carried out.
Tests: Every